Wavetek Meterman Test Tools NSN Parts: FG2C - LCR55A

Get a Quote

 

FSC 6625 Electrical and Electronic Properties Measuring and Testing Instruments

MFG SKUNSNItem NameDetailsCAGE CodeRFQ
FG2C6625-01-592-2710Generator, Function, Electronic TeSpecial Features: Frequency range: 0.3HZ to 3.MHZ, main output: >20VP-P open circuit, >10VP-P into 50LOAD, dc offset control: -10 to +10V (open)/ -5V to +5V (50LOAD), duty cycle: 80%: 20%: 80% cont, input impedance: 10K + or -10%, resolution: 300DPI, operating temp: 0 to 40 degrees celsius altitude up to 2000M, storage temp: -10 to 70 degrees celsius, power source: 115VAC or 230VAC, + or - 15%, 50/60HZ
Overall Length: 243.0 millimeters nominal
Overall Width: 292.0 millimeters nominal
44D86

Quote

VT2016625-01-545-5660Indicator, Electrical PotentialSpecial Features: 70-400 vac; 50/60 hz; approximate 2 inch operating distance; non-contact; black pushbutton actuator; red led display blinks and beeper increases in frequency as proximity to voltage increases
44D86

Quote

27XT6625-01-547-2058MultimeterSpecial Features: Additional electrical characteristics - ac current 0.4 amps at plus or minus(porm) 2.0 pct. of reading plus 10 digits, 10.0 amps at porm 2.5 pct. of reading plus 10 digits; dc current: 10.0 amps at porm 1.5 pct. of reading plus 10 digits; resistance: 10.0 megaohms porm 1.0 pct. of reading plus 10 digits, 40.0 megaohms porm 2.0 pct. of reading plus 10 digits; dc current: 100.0 microamps porm 0.5 pct. of reading plus 10 digits; volts ac: 750.0 volts porm 2.0 pct. of reading plus 10 digits; specifications at plus 23.0 degrees C. porm 5.0 degrees with less than 75.0 pct. relative humidity non-condensing; operating temperature 0.0 to 45.0 degrees C. at less than 70.0 pct. relative humidity; storage temperature minus 20.0 to 60.0 degrees C. at maximum 80.0 percent relative humidity with battery removed from meter; altitude 2000.0 meters; weight 450.0 grams
Overall Length: 195.0 millimeters nominal
Overall Width: 92.0 millimeters nominal
44D86

Quote

37XR6625-01-547-2058MultimeterSpecial Features: Additional electrical characteristics - ac current 0.4 amps at plus or minus(porm) 2.0 pct. of reading plus 10 digits, 10.0 amps at porm 2.5 pct. of reading plus 10 digits; dc current: 10.0 amps at porm 1.5 pct. of reading plus 10 digits; resistance: 10.0 megaohms porm 1.0 pct. of reading plus 10 digits, 40.0 megaohms porm 2.0 pct. of reading plus 10 digits; dc current: 100.0 microamps porm 0.5 pct. of reading plus 10 digits; volts ac: 750.0 volts porm 2.0 pct. of reading plus 10 digits; specifications at plus 23.0 degrees C. porm 5.0 degrees with less than 75.0 pct. relative humidity non-condensing; operating temperature 0.0 to 45.0 degrees C. at less than 70.0 pct. relative humidity; storage temperature minus 20.0 to 60.0 degrees C. at maximum 80.0 percent relative humidity with battery removed from meter; altitude 2000.0 meters; weight 450.0 grams
Overall Length: 195.0 millimeters nominal
Overall Width: 92.0 millimeters nominal
44D86

Quote

37XR-A
37XRA
6625-01-547-2058MultimeterSpecial Features: Additional electrical characteristics - ac current 0.4 amps at plus or minus(porm) 2.0 pct. of reading plus 10 digits, 10.0 amps at porm 2.5 pct. of reading plus 10 digits; dc current: 10.0 amps at porm 1.5 pct. of reading plus 10 digits; resistance: 10.0 megaohms porm 1.0 pct. of reading plus 10 digits, 40.0 megaohms porm 2.0 pct. of reading plus 10 digits; dc current: 100.0 microamps porm 0.5 pct. of reading plus 10 digits; volts ac: 750.0 volts porm 2.0 pct. of reading plus 10 digits; specifications at plus 23.0 degrees C. porm 5.0 degrees with less than 75.0 pct. relative humidity non-condensing; operating temperature 0.0 to 45.0 degrees C. at less than 70.0 pct. relative humidity; storage temperature minus 20.0 to 60.0 degrees C. at maximum 80.0 percent relative humidity with battery removed from meter; altitude 2000.0 meters; weight 450.0 grams
Overall Length: 195.0 millimeters nominal
Overall Width: 92.0 millimeters nominal
44D86

Quote

AM86625-01-558-8627MultimeterSpecial Features: Analog multimeter W/holster, 2M ohm resistance. battery life 200 hrs, oerating range 0 degree C to 60 degree C. overload protection all ranges 200 ma 250 volt glass fuse. dc voltage 2.5, 10V, 50V, 500V. ac voltage 50-60HZ 10V, 50V, 500V
Installation Design: Hand held
Circuit Current for Which Designed: Ac and dc
44D86

Quote

AM8B6625-01-587-3804MultimeterSpecial Features: Dc voltage ranges: 2.5 V, 10 V, 250 V, 500 v; ac voltage ranges: 10 V, 50 V, 500 V
Overall Width: 2.600 inches nominal
Installation Design: Hand held
44D86

Quote

AM8C6625-01-587-3804MultimeterSpecial Features: Dc voltage ranges: 2.5 V, 10 V, 250 V, 500 v; ac voltage ranges: 10 V, 50 V, 500 V
Overall Width: 2.600 inches nominal
Installation Design: Hand held
44D86

Quote

DM73B6625-01-272-0918MultimeterSpecial Features: Two batteries compartments to hold two LR-44 button batteries made from alkaline-manganese
Overall Length: 6.500 inches nominal
Overall Width: 1.100 inches nominal
44D86

Quote

DM73C6625-01-272-0918MultimeterSpecial Features: Two batteries compartments to hold two LR-44 button batteries made from alkaline-manganese
Overall Length: 6.500 inches nominal
Overall Width: 1.100 inches nominal
44D86

Quote

DM78A6625-01-534-8776MultimeterSpecial Features: 4200 and 3200 count resolution; analog bargraph, DM78A, ; autoranging; data hold; diod test, DM78A; continuity test with beeper; simple, one-handed operation; auto-off for extended battery life
Installation Design: Hand held
Style Designator: Hand-held
44D86

Quote

HV-231-10
HV23110
6625-01-545-5734Probe-Lead Assembly, TestSpecial Features: Hand held; ac or dc high voltage; used with standard multimeters with 10 ohm input impedance; 1000 mega ohm input resistance; 1000:1 division ratio; 40 kv ac or dc peak working voltage; 0-50 deg C operating temperature; 39 in. cable length
44D86

Quote

LCR55A6625-01-568-3263Test set, Semiconductor DeviceWidth: 38.0 millimeters nominal
Length: 183.0 millimeters nominal
Depth: 79.0 millimeters nominal
44D86

Quote