Custom Control Sensors International NSN Parts: 250F140-19 - 250F51-1

Get a Quote

 

FSC 5930 Switches

MFG SKUNSNItem NameDetailsCAGE CodeRFQ
250F140-19
250F14019
5930-01-196-9321Switch, Flow09049

Quote

250F144-2
250F1442
5930-01-492-6870Switch, FlowIII End Item Identification: Radar, RAT-31SL
09049

Quote

250F147-1
250F1471
5930-01-328-5443Switch, FlowMounting Method: Inlet connection
Overall Length: 2.620 inches minimum and 2.820 inches maximum
Nonpile-up Contact Arrangement: 1 pole, double throw, one position momentary
09049

Quote

250F147-5
250F1475
5930-01-328-5444Switch, FlowMounting Method: Inlet connection
Overall Length: 2.620 inches minimum and 2.820 inches maximum
Nonpile-up Contact Arrangement: 1 pole, double throw, one position momentary
09049

Quote

250F148-1
250F1481
5930-01-349-9847Switch, FlowNonpile-up Contact Arrangement: 1 pole, double throw, one position momentary
Terminal Type: Connector, receptacle
Contact Load Current Rating: 25.0 milliamperes resistive load first voltage 50.0 milliamperes resistive load second voltage
09049

Quote

250F175930-00-789-4970Switch, FlowMounting Method: Line and inlet connection and outlet connection
Overall Length: 4.250 inches maximum
Nonpile-up Contact Arrangement: 1 pole, single throw, normally closed, momentary action
09049

Quote

250F17-1
250F171
5930-00-010-0386Switch, FlowMounting Method: Inlet connection and outlet connection
Overall Length: 4.250 inches maximum
Nonpile-up Contact Arrangement: 1 pole, single throw, normally closed, momentary action
09049

Quote

250F35-1
250F351
5930-00-949-3317Switch, Flow09049

Quote

250F35A-1
250F35A1
5930-00-949-3317Switch, Flow09049

Quote

250F35A65930-00-311-6484Switch, FlowMounting Method: LINE
Overall Length: 2.750 inches maximum
Nonpile-up Contact Arrangement: 1 pole, single throw, normally open, momentary action
09049

Quote

250F42-1
250F421
5930-00-918-4294Switch, FlowSpecial Features: Hermetically sealed enclosure 3.250 in. lg; 1.250 in. h; 2.380 in. dia; spdt contacts; open on increasing flow at 0.85 gpm; close on decreasing flow at 0.60 gpm; rate of 3 amps inductive at 28 V dc; 0.5 amps inductive at 50 V dc; dielectric withstanding voltage 1000 V rms; insulation resistance 1000 megohms; working pressure 25 to 75 psig; proof pressure 150 psig; burst pressure 300 psig; pressure drop of 5 psi at flow of 1 gpm
09049

Quote

250F42-13
250F4213
5930-01-094-2269Switch, FlowMounting Method: Threaded hole and line
Overall Length: 2.940 inches nominal
Nonpile-up Contact Arrangement: 1 pole, double throw, one position momentary
09049

Quote

250F42-2
250F422
5930-00-918-4315Switch, FlowOverall Length: 2.500 inches minimum and 3.270 inches maximum
Overall Height: 3.910 inches maximum
Overall Width: 2.400 inches maximum
09049

Quote

250F42-3
250F423
5930-00-918-4314Switch, FlowOverall Length: 3.250 inches nominal
Nonpile-up Contact Arrangement: 1 pole, double throw, one position momentary
Contact Load Current Rating: 3.0 amperes inductive load first voltage 0.5 amperes inductive load second voltage
09049

Quote

250F42-4
250F424
5930-00-918-4289Switch, FlowOverall Length: 3.250 inches nominal
Nonpile-up Contact Arrangement: 1 pole, double throw, one position momentary
Overall Height: 2.840 inches nominal
09049

Quote

250F42-5
250F425
5930-00-918-4295Switch, FlowOverall Length: 3.250 inches nominal
Nonpile-up Contact Arrangement: 1 pole, double throw, one position momentary
Overall Height: 2.840 inches nominal
09049

Quote

250F42-6
250F426
5930-00-419-7634Switch, FlowOverall Length: 3.250 inches nominal
Nonpile-up Contact Arrangement: 1 pole, double throw, one position momentary
Overall Height: 2.840 inches nominal
09049

Quote

250F42-7
250F427
5930-00-419-7635Switch, FlowOverall Length: 3.250 inches nominal
Nonpile-up Contact Arrangement: 1 pole, double throw, one position momentary
Overall Height: 2.840 inches nominal
09049

Quote

250F55930-00-891-8676Switch, Flow09049

Quote

250F51-1
250F511
5930-00-891-8673Switch, FlowMounting Method: Inlet connection and outlet connection
Overall Length: 3.546 inches maximum
Nonpile-up Contact Arrangement: 1 pole, single throw, normally open, momentary action
09049

Quote