Abbott Laboratories NSN Parts: 04J50-22 - 3L36-01
FSC 6550 In Vitro Diagnostic Substances, Reagents, Test Kits and Sets
MFG SKU | NSN | Item Name | Details | CAGE Code | RFQ |
---|---|---|---|---|---|
04J50-22 04J5022 | 6550-01-521-5358 | Control, Blood Chemistry | Protective Storage Feature: Requires refrigeration between 2 deg to 8 deg C Primary Container Type: Ampul Primary Container Content Quantity: 1.000 milliliters | 33110 | |
06F12-01 06F1201 | 6550-01-431-8279 | Control, Blood Chemistry | Usage Design: For use W/G, E3+, G3+, EC4+, 6+, EG6+, EC6+ and EC8 cartridges; I-stat level 1 (low) control Primary Container Type: Ampul Primary Container Content Quantity: 1.700 milliliters | 33110 | |
06F12-04 06F1204 | 6550-01-534-4571 | Control, Blood Chemistry | Special Features: 3 levels for moitoring cartridge performance at different points within the clinical range; the controls ar packaged in sealed glass ampules, each containing 1.7ML of solution; ampules are packaged ten per box; buffered aqueous solution containing electrolytes and non-conductive ingredients; contains no red cells or biological materiel; requires storage between 2-25 deg.C Part Name Assigned BY Controlling Agency: I-stat hct level 1 control Primary Container Type: Ampul | 33110 | |
06F12-05 06F1205 | 6550-01-534-3661 | Control, Blood Chemistry | Special Features: 3 levels for monitoring cartridge performance at different points within the clonical range; the controls are packaged in sealed glass amupules, each containing 1.7ML of solution; ampules are packaged in 10 per box; buffered aqueous sloution containing electrolytes and non-conductive ingredients; contains no red cells or biological material; requires storage between 2-25 degrees C | 33110 | |
06F12-06 06F1206 | 6550-01-534-4595 | Control, Blood Chemistry | Special Features: 3 levels for moitoring cartridge performance at different points within the clinical range; the controls ar packaged in sealed glass ampules, each containing 1.7ML of solution; ampules are packaged ten per box; buffered aqueous solution containing electrolytes and non-conductive ingredients; contains no red cells or biological materiel; requires storage between 2-25 deg.C Part Name Assigned BY Controlling Agency: I-stat hct level 3 control Primary Container Type: Ampul | 33110 | |
06F12-07 06F1207 | 6550-01-534-3462 | Control, Blood Chemistry | Special Features: 5 levels for verifying the accuracy of hematocrit measurements throughout the reportable range; ampules are packaged in kits containing four ampules of each level; the controls are packaged in sealed glass ampules, each containing 1.7ML of solution; buffered aquesous solution containing electrolytes and non-conductive ingredients; contains no red cells or biological material; requires storage; requires storage between 2-25 deg. C Primary Container Type: Ampul Total Primary Container Quantity: 20 | 33110 | |
06F13-01 06F1301 | 6550-01-432-3688 | Control, Blood Chemistry | Part Name Assigned BY Controlling Agency: Control bld chem use W/G E3+G3+EC4+6+EG6*EC6+&EC8+CARTRIDGE1.7ML Primary Container Type: Ampul Primary Container Content Quantity: 1.700 milliliters | 0TDX9, 33110 | |
06F13-02 06F1302 | 6550-01-521-5315 | Control, Blood Chemistry | Special Features: Cardiac control reagent, level 2; aids in diagnosis of myocardial infarct by verifying correct performance of test cartridge for troponini i; level 2 cardiac control; pkg. of 6 X 1.0ML; refrigeration is required; for use on chemistry analyzer, nsn: 6630-01-520-5212 Primary Container Type: Ampul Primary Container Content Quantity: 1.000 milliliters | 33110 | |
06F14-01 06F1401 | 6550-01-432-3696 | Control, Blood Chemistry | Usage Design: For use with G, E3+, G3+, EC4+, 6+, EG6+, EC6+, and EC8 Primary Container Type: Ampul Primary Container Content Quantity: 1.700 milliliters | 0MRZ6, 0TDX9 | |
06F14-02 06F1402 | 6550-01-521-5335 | Control, Blood Chemistry | Protective Storage Feature: Requires refrigeration between 2 deg to 8 deg C Primary Container Type: Ampul Primary Container Content Quantity: 1.000 milliliters | 33110 | |
CARDIAC MARKER CONTROL CARDIACMARKERCONTROL | 6550-01-521-5335 | Control, Blood Chemistry | Protective Storage Feature: Requires refrigeration between 2 deg to 8 deg C Primary Container Type: Ampul Primary Container Content Quantity: 1.000 milliliters | 33110 | |
HCTLEVEL1 | 6550-01-534-4571 | Control, Blood Chemistry | Special Features: 3 levels for moitoring cartridge performance at different points within the clinical range; the controls ar packaged in sealed glass ampules, each containing 1.7ML of solution; ampules are packaged ten per box; buffered aqueous solution containing electrolytes and non-conductive ingredients; contains no red cells or biological materiel; requires storage between 2-25 deg.C Part Name Assigned BY Controlling Agency: I-stat hct level 1 control Primary Container Type: Ampul | 33110 | |
HCTLEVEL2 | 6550-01-534-3661 | Control, Blood Chemistry | Special Features: 3 levels for monitoring cartridge performance at different points within the clonical range; the controls are packaged in sealed glass amupules, each containing 1.7ML of solution; ampules are packaged in 10 per box; buffered aqueous sloution containing electrolytes and non-conductive ingredients; contains no red cells or biological material; requires storage between 2-25 degrees C | 33110 | |
HCTLEVEL3 | 6550-01-534-4595 | Control, Blood Chemistry | Special Features: 3 levels for moitoring cartridge performance at different points within the clinical range; the controls ar packaged in sealed glass ampules, each containing 1.7ML of solution; ampules are packaged ten per box; buffered aqueous solution containing electrolytes and non-conductive ingredients; contains no red cells or biological materiel; requires storage between 2-25 deg.C Part Name Assigned BY Controlling Agency: I-stat hct level 3 control Primary Container Type: Ampul | 33110 | |
I-STAT CARDIAC MARKER CONTROL ISTATCARDIACMARKERCONTROL | 6550-01-521-5315 | Control, Blood Chemistry | Special Features: Cardiac control reagent, level 2; aids in diagnosis of myocardial infarct by verifying correct performance of test cartridge for troponini i; level 2 cardiac control; pkg. of 6 X 1.0ML; refrigeration is required; for use on chemistry analyzer, nsn: 6630-01-520-5212 Primary Container Type: Ampul Primary Container Content Quantity: 1.000 milliliters | 33110 | |
I-STAT LEVEL 1 AQUEOUS CONTROL ISTATLEVEL1AQUEOUSCONTROL | 6550-01-431-8279 | Control, Blood Chemistry | Usage Design: For use W/G, E3+, G3+, EC4+, 6+, EG6+, EC6+ and EC8 cartridges; I-stat level 1 (low) control Primary Container Type: Ampul Primary Container Content Quantity: 1.700 milliliters | 33110 | |
I-STAT LEVEL 1 PT CONTROL ISTATLEVEL1PTCONTROL | 6550-01-521-5361 | Control, Blood Chemistry | III Protective Storage Feature: Requires refrigeration storage between 2 to 8 deg celsius Primary Container Type: Ampul Primary Container Content Quantity: 1.000 milliliters | 33110 | |
I-STAT LEVEL 2 PT CONTROL ISTATLEVEL2PTCONTROL | 6550-01-521-5358 | Control, Blood Chemistry | Protective Storage Feature: Requires refrigeration between 2 deg to 8 deg C Primary Container Type: Ampul Primary Container Content Quantity: 1.000 milliliters | 33110 | |
ISTHCTCALVER | 6550-01-534-3462 | Control, Blood Chemistry | Special Features: 5 levels for verifying the accuracy of hematocrit measurements throughout the reportable range; ampules are packaged in kits containing four ampules of each level; the controls are packaged in sealed glass ampules, each containing 1.7ML of solution; buffered aquesous solution containing electrolytes and non-conductive ingredients; contains no red cells or biological material; requires storage; requires storage between 2-25 deg. C Primary Container Type: Ampul Total Primary Container Quantity: 20 | 33110 | |
3L36-01 3L3601 | 6550-01-578-3523 | Control, Ethyl Alcohol | Special Features: Intended for the quantitative determination of ethanol in human urine, serum, and plasma on the architect C8000 system, the architect C16000 system, and the aeroset system | 33110 |