ABHP | Overall Length | 3.500 inches nominal |
ABKW | Overall Height | 0.900 inches nominal |
ABMK | Overall Width | 2.900 inches nominal |
ADJH | Mounting Method | CLIP |
AFJU | Carrying Case | Not provided |
ALSF | Internal Battery Accommodation | Included |
AMKD | Indicator Type | Audio and visual |
AMRX | Detecting Element Type | Geiger tube |
APCB | Portability | Portable |
CTJX | Dose Rate per Hour | +0.0 to 500.0 rad |
CXCY | Part Name Assigned BY Controlling Agency | Doserae electronic personal dosimeter |
FEAT | Special Features | Extended 0 to 999 sv, 0 to 999 R, dose range; easy-to-read autoranging lcd provides dose, dose rate and stay-time information; a single aa battery lasts more than 750 hours; dose history stores 200 data points; dust and shock resistant; long calibration life; provides does readings with a resolution of less than 0.02 usv, 2 ur; alerts wearer with a loud 75 plus db alarm at 30 cm for noisy environments and big, bright flashing leds; energy response tissue equivalent to porm 25 pct from 55 kev to 6 mev; no fold over up to 100 sv/h; user calibration recommended at least every 2 years; factory calibration not required; datalog interval 6 S to 109 H |
FTLD | Functional Description | Rugged, lightweight, direct-reading electronic personal dosimeter that provides superior dose monitoring accuracy |
SUPP | Supplementary Features | Operating enviroment temperature M28.0 to P60.0 deg c; humidity 0 to 95 pct non-condensing; shock resistance passes drop test from 1 M, 39 inch onto concrete; ip rating IP54; built-in continous self-test monitors power supply and G-M tube; abnormal operation indicated on lcd; weight 130 G |