| ABHP | Overall Length | 1.718 inches maximum |
| ABKR | Center to Center Distance Between Mounting Facilities Parallel to Width | 0.625 inches nominal single mounting facility |
| ABKW | Overall Height | 1.645 inches maximum |
| ABMK | Overall Width | 1.025 inches maximum |
| ABTD | Mounting Slot Width | 0.150 inches nominal single mounting facility |
| ADTV | Case Material | Metal |
| ADZC | Environmental Protection | Hermetic |
| AFJN | Fragility Factor | Moderately rugged |
| AKDX | Winding Quantity | 1 |
| AKSL | Purpose for Which Designed | General |
| APCN | Coil Quantity | 1 |
| APNP | Duty Type | Continuous |
| APNQ | ARC Quenching Method | AIR |
| AXHR | Mounting Facility Type and Quantity | 3 slotted hole single mounting facility |
| BBRG | Storage Type | General purpose warehouse |
| CBBL | Features Provided | Polarized |
| CBME | Cubic Measure | 2.897 cubic inches |
| CQYJ | Mounting Facility Pattern | Triangle single mounting facility |
| CRNG | Nonpile-up Main Contact Arrangement | 3 pole, double throw, one position momentary |
| CRPQ | Nominal Operating Current Rating and Type | 120.0 milliamperes dc single winding |
| CRXH | Time Delay | 0.015 seconds maximum fixed operate and release time |
| CSQJ | Center to Center Distance Between Mounting Facilities Parallel to the Altitude of AN Isosceles Triangle | 1.471 inches nominal single mounting facility |
| CSXF | Operating Voltage Rating and Type at Specified Temp | 28.0 volts dc 25 deg celsius single winding |
| CTDL | Main Contact Load Current Rating at Maximum Rated Voltage | 10.0 amperes ac motor load and 10.0 amperes dc motor load |
| CTDL | Main Contact Load Current Rating at Maximum Rated Voltage | 25.0 amperes ac resistive load and 25.0 amperes dc resistive load |
| CTDL | Main Contact Load Current Rating at Maximum Rated Voltage | 5.0 amperes ac lamp load and 5.0 amperes dc lamp load |
| CWAB | Main Contact Maximum Voltage Rating in Volts | 115.0 ac and 28.0 dc |
| TEST | Test Data Document | 81349-MIL-R-6106 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.). |
| TTQY | Terminal Type and Quantity | 11 wire hook all functions |
| ZZZK | Specification/Standard Data | 96906-MS27743 government standard |