| ABHP | Overall Length | 3.700 inches maximum |
| ABKQ | Center to Center Distance Between Mounting Facilities Parallel to Length | 3.250 inches nominal single mounting facility |
| ABKR | Center to Center Distance Between Mounting Facilities Parallel to Width | 2.687 inches nominal single mounting facility |
| ABKW | Overall Height | 4.475 inches nominal |
| ABMK | Overall Width | 3.305 inches maximum |
| ADZC | Environmental Protection | Hermetic |
| AEBV | Unthreaded Mounting Hole Diameter | 0.297 inches minimum single mounting facility |
| AFJN | Fragility Factor | Moderately rugged |
| AJSS | Frequency in Hertz | 60.0 nominal or 400.0 nominal |
| AKDX | Winding Quantity | 1 |
| AKSL | Purpose for Which Designed | General |
| APCN | Coil Quantity | 1 |
| APNP | Duty Type | Continuous |
| APNQ | ARC Quenching Method | AIR |
| AXHR | Mounting Facility Type and Quantity | 4 unthreaded hole single mounting facility |
| BBRG | Storage Type | General purpose warehouse |
| CBME | Cubic Measure | 54.722 cubic inches |
| CQYJ | Mounting Facility Pattern | Rectangular single mounting facility |
| CRNG | Nonpile-up Main Contact Arrangement | 3 pole, single throw, normally open, double make, momentary action |
| CRPQ | Nominal Operating Current Rating and Type | 225.0 milliamperes ac single winding |
| CRXH | Time Delay | 0.03 seconds nominal fixed operate time |
| CRXH | Time Delay | 0.065 seconds nominal fixed release time |
| CSKP | Nonpile-up Auxiliary Contact Arrangement | 1 two circuit, double break/double make, one position momentary |
| CSQC | Auxiliary Contact Maximum Voltage Rating in Volts | 115.0 ac and 28.0 dc |
| CSXF | Operating Voltage Rating and Type at Specified Temp | 115.0 volts ac 25 deg celsius single winding |
| CTDL | Main Contact Load Current Rating at Maximum Rated Voltage | 50.0 amperes ac resistive load and 50.0 amperes dc resistive load |
| CTDL | Main Contact Load Current Rating at Maximum Rated Voltage | 50.0 amperes ac motor load and 50.0 amperes dc motor load |
| CWAB | Main Contact Maximum Voltage Rating in Volts | 115.0 ac and 28.0 dc |
| CWGM | Auxiliary Contact Load Current Rating at Maximum Rated Voltage | 5.0 amperes ac resistive load and 5.0 amperes dc resistive load |
| CWGM | Auxiliary Contact Load Current Rating at Maximum Rated Voltage | 750.0 milliamperes ac lamp load and 750.0 milliamperes dc lamp load |
| TEST | Test Data Document | 81349-MIL-R-6106 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.). |
| TTQY | Terminal Type and Quantity | 12 threaded stud all functions |
| ZZZK | Specification/Standard Data | 96906-MS24376 government standard |