AAJD | Thread Class | 2A single mounting facility |
AAJF | Thread Direction | Right-hand single mounting facility |
ABHP | Overall Length | 1.531 inches maximum |
ABKQ | Center to Center Distance Between Mounting Facilities Parallel to Length | 1.187 inches nominal single mounting facility |
ABKR | Center to Center Distance Between Mounting Facilities Parallel to Width | 1.187 inches nominal single mounting facility |
ABKW | Overall Height | 2.187 inches nominal |
ABMK | Overall Width | 1.531 inches maximum |
ADTV | Case Material | Metal |
ADZC | Environmental Protection | Hermetic |
AFJN | Fragility Factor | Moderately rugged |
AKDX | Winding Quantity | 2 |
AKSL | Purpose for Which Designed | General |
APCN | Coil Quantity | 2 |
APNP | Duty Type | Continuous |
APNQ | ARC Quenching Method | AIR |
AXHR | Mounting Facility Type and Quantity | 4 threaded stud single mounting facility |
BBRG | Storage Type | General purpose warehouse |
CBBL | Features Provided | Latching contacts and polarized |
CBME | Cubic Measure | 5.271 cubic inches |
CMLP | Thread Quantity per Inch | 32 single mounting facility |
CQJX | Nominal Thread Size | 0.138 inches single mounting facility |
CQYJ | Mounting Facility Pattern | Rectangular single mounting facility |
CRNG | Nonpile-up Main Contact Arrangement | 4 pole, double throw, one position momentary |
CRXH | Time Delay | 0.025 seconds maximum fixed operate time |
CSXF | Operating Voltage Rating and Type at Specified Temp | 115.0 volts ac 25 deg celsius first winding |
CSXF | Operating Voltage Rating and Type at Specified Temp | 28.0 volts dc 25 deg celsius second winding |
CTDL | Main Contact Load Current Rating at Maximum Rated Voltage | 10.0 amperes ac resistive load and 10.0 amperes dc resistive load |
CTDL | Main Contact Load Current Rating at Maximum Rated Voltage | 10.0 amperes ac inductive load and 6.0 amperes dc inductive load |
CTDL | Main Contact Load Current Rating at Maximum Rated Voltage | 2.0 amperes ac lamp load and 2.0 amperes dc lamp load |
CTDL | Main Contact Load Current Rating at Maximum Rated Voltage | 4.0 amperes ac motor load and 4.0 amperes dc motor load |
CWAB | Main Contact Maximum Voltage Rating in Volts | 115.0 ac and 28.0 dc |
TEST | Test Data Document | 81349-MIL-R-6106 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.). |
THSD | Thread Series Designator | Unc single mounting facility |
TTQY | Terminal Type and Quantity | 16 wire hook all functions |
ZZZK | Specification/Standard Data | 96906-MS25468 government standard |