ABHP | Overall Length | 1.718 inches maximum |
ABKR | Center to Center Distance Between Mounting Facilities Parallel to Width | 0.625 inches nominal single mounting facility |
ABKW | Overall Height | 1.420 inches maximum |
ABMK | Overall Width | 1.025 inches maximum |
ABTD | Mounting Slot Width | 0.150 inches nominal single mounting facility |
ADTV | Case Material | Metal |
ADZC | Environmental Protection | Hermetic |
AFJN | Fragility Factor | Moderately rugged |
AJSS | Frequency in Hertz | 400.0 nominal |
AKDX | Winding Quantity | 1 |
AKSL | Purpose for Which Designed | General |
APCN | Coil Quantity | 1 |
APNP | Duty Type | Continuous |
APNQ | ARC Quenching Method | AIR |
AXHR | Mounting Facility Type and Quantity | 3 slotted hole single mounting facility |
BBRG | Storage Type | General purpose warehouse |
CBBL | Features Provided | Polarized |
CBME | Cubic Measure | 2.500 cubic inches |
CQYJ | Mounting Facility Pattern | Triangle single mounting facility |
CRNG | Nonpile-up Main Contact Arrangement | 4 pole, double throw, one position momentary |
CRXH | Time Delay | 0.02 seconds maximum fixed operate time |
CRXH | Time Delay | 0.05 seconds maximum fixed release time |
CSQJ | Center to Center Distance Between Mounting Facilities Parallel to the Altitude of AN Isosceles Triangle | 1.446 inches nominal single mounting facility |
CSXF | Operating Voltage Rating and Type at Specified Temp | 115.0 volts ac 25 deg celsius single winding |
CTDL | Main Contact Load Current Rating at Maximum Rated Voltage | 10.0 amperes ac resistive load and 10.0 amperes dc resistive load |
CTDL | Main Contact Load Current Rating at Maximum Rated Voltage | 2.0 amperes ac lamp load and 2.0 amperes dc lamp load |
CTDL | Main Contact Load Current Rating at Maximum Rated Voltage | 4.0 amperes ac motor load and 4.0 amperes dc motor load |
CTDL | Main Contact Load Current Rating at Maximum Rated Voltage | 8.0 amperes ac inductive load and 8.0 amperes dc inductive load |
CWAB | Main Contact Maximum Voltage Rating in Volts | 115.0 ac and 28.0 dc |
TEST | Test Data Document | 81349-MIL-R-6106 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.). |
TTQY | Terminal Type and Quantity | 14 wire hook all functions |
ZZZK | Specification/Standard Data | 96906-MS27400 government standard |