ABFE | Hazardous Locations/Environmental Protection | Humidity resistant and vibration resistant |
ABHP | Overall Length | 32.0 millimeters nominal |
ABKW | Overall Height | 12.0 millimeters nominal |
ABPM | Body Diameter | 16.0 millimeters nominal |
AEJN | Distance Between Mounting Facility Centers | 24.0 millimeters nominal |
AKBY | Temp Sensing Element Type | DISC |
AWTN | Operating Temp Rating | 65.0 deg celsius minimum and 85.0 deg celsius maximum |
AXGY | Mounting Method | Bracket |
CBBL | Features Provided | Automatic reset |
CQGB | Contact Action Stimulus | Increase |
CQYJ | Mounting Facility Pattern | Two position in-line |
CSCF | Terminal Type | Quick disconnect, male |
CTYC | Contact Adjustability | Actuation point not adjustable and deactuation point not adjustable |
CTZB | Contact Voltage Rating in Volts | 120.0 ac at sea level first voltage |
CTZB | Contact Voltage Rating in Volts | 30.0 dc at sea level second voltage |
FEAT | Special Features | Important - when ordering must specify operating temperature range - open 80 deg. C. plus or minus 5 deg. C. - close 70 deg. C. plus or minus 5 deg. c; part name assigned by controlling agency - bimetallic disc thermostat; shock resistant; single pole double throw; normally closed; open on rise; contact point 1 to 100 milliamps; phenolic body; aluminum open cap; stainless steel adjustable mounting bracket |
MEDA | Media for Which Designed | GAS |
STYL | Style Designator | Disc W/flange |