AAJE | Thread Pitch Diameters | +0.3503 to 0.3537 inches |
AAQL | Body Style | Multipole-single actuator type |
ABXD | Bushing Length | 0.332 inches minimum and 0.380 inches maximum |
ADAQ | Body Length | 1.531 inches minimum and 1.562 inches maximum |
ADAT | Body Width | 1.250 inches minimum and 1.281 inches maximum |
AEBP | Center to Center Distance Between Terminals Parallel to Length | 0.875 inches minimum and 0.906 inches maximum |
AEBQ | Center to Center Distance Between Terminals Parallel to Width | 0.594 inches minimum and 0.906 inches maximum |
AJWX | Mounting Surface to Terminal End Distance | 1.797 inches minimum and 1.828 inches maximum |
AKPX | Pole Quantity | 2 |
AXHR | Mounting Facility Type and Quantity | 1 threaded bushing W/panel seal |
CMLP | Thread Quantity per Inch | 32 |
CPLM | Maximum Continuous Load Current Rating per Pole | 5.0 amperes ac and 5.0 amperes dc all locations |
CPRF | Operating Voltage Type and Rating per Pole in Volts | 240.0 ac and 50.0 dc all locations |
CPRG | Maximum Interrupting Capacity Current Type and Rating per Pole in Amps | 300.0 ac and 500.0 dc all locations |
CPRH | Circuit Protection Type | Overcurrent all locations |
CPRJ | Trip Release Method | Magnetic all locations |
CPRL | Trip Release Characteristic | Time delay all locations |
CPRN | Ultimate Trip Rating of Continuous Current Rating per Pole in Percent | 125.0 all locations |
CPRQ | Reset Method | Manual |
CPRR | Main Contact Tripping Mechanism Type | Trip free |
CPRT | Manual Actuator Type and Quantity | 1 toggle |
CPRW | Actuator Function | Trip-reset |
CPRX | Actuator Position Designation | Between pole one and two |
CPSM | Internal Trip Release Configuration | Series trip all locations |
CQJX | Nominal Thread Size | 0.375 inches |
CQWN | Trip Delay Time in Seconds per Rated Continuous Current | 0.500 minimum at 200 pct and 0.900 maximum at 200 pct all locations |
FREQ | Frequency in Hertz | 400.0 all locations |
THSD | Thread Series Designator | UNEF |
TTQY | Terminal Type and Quantity | 4 wire hook |