5925-00-942-6963 (AM12HK05-32VDC5) Data

5925-00-942-6963 (5925009426963) NSN Information

PhotoNSNFSCNIINItem NameINC
5925-00-942-6963 Photo
5925-00-942-69635925009426963Circuit Breaker00136

5925-00-942-6963 Features

MRCParameterCharacteristics
AAQLBody StyleSingle pole type
ADAQBody Length2.500 inches nominal
ADATBody Width0.750 inches nominal
AEBPCenter to Center Distance Between Terminals Parallel to Length1.938 inches nominal
AEBYDistance Between Centerlines of Mounting Facilities Parallel to Body Length2.062 inches nominal
AEGJSwitch Contact ArrangementSingle pole, double throw
AFJNFragility FactorModerately rugged
AGAVEnd Item IdentificationEngine generator (eg)
AJECBoss Height0.140 inches nominal
AJWXMounting Surface to Terminal End Distance2.611 inches nominal
AKPXPole Quantity1
APNQARC Quenching MethodAIR
AXHRMounting Facility Type and Quantity2 threaded hole
BBRGStorage TypeGeneral purpose warehouse
CMLPThread Quantity per Inch32
CPLMMaximum Continuous Load Current Rating per Pole500.0 milliamperes dc single location
CPRFOperating Voltage Type and Rating per Pole in Volts32.0 dc single location
CPRGMaximum Interrupting Capacity Current Type and Rating per Pole in Amps2000.0 dc single location
CPRHCircuit Protection TypeOvercurrent single location
CPRJTrip Release MethodMagnetic-hydraulic single location
CPRLTrip Release CharacteristicTime delay single location
CPRNUltimate Trip Rating of Continuous Current Rating per Pole in Percent125.0 single location
CPRQReset MethodManual
CPRRMain Contact Tripping Mechanism TypeTrip free
CPRTManual Actuator Type and Quantity1 toggle
CPRWActuator FunctionTrip-reset
CPRXActuator Position DesignationAt pole one
CPRZAuxiliary Switch Function and Quantity1 alarm
CPSMInternal Trip Release ConfigurationSeries trip single location
CQJXNominal Thread Size0.138 inches
CQSMSwitch Location and Position DesignationInternal at pole one
CQWNTrip Delay Time in Seconds per Rated Continuous Current0.250 minimum at 200 pct and 0.750 maximum at 200 pct single location
CQXFInclosure Protection Type for Which DesignedDustproof
CRTKSwitch Terminal TypeTab, solder lug
CSSXSwitch Current Rating and Type in Amps2.5 ac and 1.0 dc
CSWPSwitch Voltage Rating and Type in Volts250.0 ac and 50.0 dc
CWJKCase MaterialPlastic
THSDThread Series DesignatorUNC
TTQYTerminal Type and Quantity2 threaded stud

5925-00-942-6963 Manufacturing Part Numbers (SKUs)

MFG SKUCAGESTATUSISCRNVCRNCCSADCDACHCCRNAAC
AM12HK05-32VDC508125A23 ZZ
AM12HK05-32VDC574193H95 ZG

5925-00-942-6963 Manufacturer

MFG SKUCAGEManufacturerTypeStatusRole
AM12HK05-32VDC574193Eaton Corp.AH
AM12HK05-32VDC508125U S Dept of TransportationAA

5925-00-942-6963 FLIS Identification

PMICADPE CODECRITL CODEDEMIL CODEDEMIL INTGNIIN ASGMTESDHMICENACSCHEDULE_BINC
UNA110-JAN-1966P853620004000136

5925-00-942-6963 Demilitarization Codes & Management

DMLPMICHMICADPECCriticalityESDC
APN

5925-00-942-6963 Non-consumable Item Support

MOE RULENIMSCDSOR
ZR01

5925-00-942-6963 Freight

NMFCNMFC SUBUFCHMCLTLLCLWCCTCCSHCADCACCASHNMF DESC