AAPN | Section Quantity | 1 |
AAQL | Body Style | Cylindrical servo mounted |
AARG | Reliability Indicator | Not established |
AAVL | Pilot Diameter | 0.7495 inches minimum and 0.7500 inches maximum |
AAVM | Pilot Length | 0.0570 inches minimum and 0.0670 inches maximum |
ABPA | Undercut Diameter | 0.781 inches maximum |
ABPC | Undercut Width | 0.0570 inches minimum and 0.0670 inches maximum |
ABPM | Body Diameter | 0.840 inches minimum and 0.850 inches maximum |
ABWV | Shaft Diameter | 0.245 inches minimum and 0.248 inches maximum |
ABXF | Shaft Length | 1.559 inches minimum and 1.621 inches maximum |
ADAQ | Body Length | 0.625 inches maximum |
AECZ | Mounting LIP Diameter | 0.8700 inches minimum and 0.8800 inches maximum |
AEDA | Mounting LIP Depth | 0.0570 inches minimum and 0.0670 inches maximum |
AEDX | Shaft Style | Round, stepped |
AEFD | Actuator Type | Double ended shaft |
AEFH | Effective Electrical Rotation in DEG Angular Rotation | 360.0 nominal |
AEFK | Maximum Starting Torque | 0.27 inch-ounces |
AEFL | Maximum Running Torque | 0.27 inch-ounces |
AEFY | Shaft End Play | 0.005 inches |
AEFZ | Shaft Runout | 0.001 inches |
AEGA | Lateral Runout | 0.002 inches |
AEGB | Pilot Diameter Runout | 0.001 inches |
AEGC | Shaft Radial Play | 0.001 inches |
AFJN | Fragility Factor | Moderately rugged |
AGQL | Undercut Length | 0.105 inches minimum and 0.115 inches maximum |
AXGY | Mounting Method | Clamp ring |
CBBL | Features Provided | Humidity proof |
CQCC | Electrical Resistance per Section | 6.0 kilohms single section |
CQCH | Tap Location from CCW Terminal per Section in DEG of Effective Electrical Rotation | 336.0 single section |
CQCK | Rotary Actuator Travel in Angular DEG | 360.0 nominal |
CQFL | Function Conformity Tolerance per Section | -0.15 to 0.15 single section |
CQGN | Ambient Temp in DEG Celsius per Section at Zero Percent Rated Power | 125.0 single section |
CQTM | Terminal Location | Radially positioned over less than half the circumference |
CRGD | Power Dissipation Rating per Section in Watts | 1.0 free air single section |
CRGM | Function Conformity per Section | Single section independent linearity |
CRJS | Fixed Tap Quantity per Section | 1 single section |
CRSS | Resistance Tolerance per Section in Percent | -10.0 to 10.0 single section |
CRSX | Actuator Travel Control Feature | Continuous motion |
CSBW | Tap Location from CCW Terminal per Section in Ohms | 150.0 single section |
CSBX | Function Characteristic per Section | Single section linear |
CSDH | Ambient Temp in DEG Celsius per Section at Full Rated Power | 70.0 single section |
CXHN | Shaft Bearing Type | BALL |
TEST | Test Data Document | 89305-484829 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing) |
TTQY | Terminal Type and Quantity | 4 turret |